Abstract
In this paper, a comprehensive controller of a standalone microgrid is implemented, which has three dispersed generation units based on a wind, solar photovoltaic (PV) array, and a diesel generator (DG). The power ratio variable step perturb and observe method is applied to achieve maximum power point tracking of a solar PV array and a variable speed wind turbine coupled a permanent magnet brushless dc generator without rotor/wind speed sensors. Moreover, to ensure perfect synchronization of a DG to the point of common coupling (PCC), a control algorithm is developed, which is based on in-phase and quadrature units. An active power control based on proportional–integral controller with anti-windup, is used for voltage and frequency regulation. The LCL filter based on virtual resistor, is used for power quality improvement at PCC. Simulation and test results are presented for the validation of the proposed system using a prototype of 2 kW in the laboratory.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.