Abstract

BackgroundExperimental surgical procedures for atrioventricular valves present promising translational capabilities, and preclinical studies are necessary to assess their applicability and to train young enthusiastic heart teams. Here, we present a synopsis of experimental surgical procedures on porcine models for mitral valvular (MV) and tricuspid valvular (TV) interventions; mitral valve-in-valve implantation (MViV), transapical cardioscopic (TAC) MV replacement (MVR), TAC-MV annuloplasty, and tricuspid valve-in-a-ring (TViR) procedures. MethodsTwenty-five (n = 25) female Yorkshire pigs of 55-65 kg is the total number used in the four approaches; seven animals underwent MViV, six TAC-MVR, six TAC-MV annuloplasty, and six TViR, respectively. All were subjected to a first conventional valvular surgery (bioprosthetic valve replacement and/or prosthetic ring repair). Then, after 4 wk, a less-invasive second surgery was performed using the transcatheter approaches under investigation. Except for the TAC-MVR and annuloplasty procedures, all animals were followed up for additional 4 wk. Results(1) MViV (n = 7): Standard MVR was successfully performed in all animals. Transvalvular pressure gradients and flow velocities were (Pmax 3.77 ± 0.8 mmHg; Pmean 2.1 ± 0.6 mmHg, Vmax 97 ± 13 cm/s; Vmean 68 ± 21 cm/s). Effective MViV followed (Pmax 16.7 ± 1.8 mmHg; Pmean 6.2 ± 1.2 mmHg, Vmax 216 ± 32 cm/s; Vmean 110 ± 24 cm/s). (2) TAC-MVR (n = 6): The overall bypass time was 177.2 ± 44.2 min. Transprosthetic Pmean was 4.6 ± 2.4 mmHg; no paravalvular leaks in all animals. (3) TAC-MV annuloplasty (n = 6): The implantation time was 47 ± 6 min. MV was competent, left ventricular ejection fraction (LV-EF%) was 63 ± 4%. (4) TViR (n = 6): Conventional TV ring repair was performed in all animals (Pmax 2.42 ± 0.7 mmHg; Pmean 1.3 ± 0.6 mmHg, Vmax 82 ± 10.4 cm/s; Vmean 65.4 ± 21 cm/s). All TViRs were implanted efficiently (Pmax 4.7 ± 1.6 mmHg; Pmean 2.7 ± 0.8 mmHg, Vmax 105 ± 31 cm/s; Vmean 81 ± 16 cm/s). A mild paravalvular leak was observed in one animal (16%). ConclusionsAll studied experimental valvular interventions are feasible, within the context of well-trained cardiac surgery specialists, and all possibilities should be considered when treating a patient to determine which one suits best his individual challenges and scope.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call