Abstract

The ion species composition in the source region of inertial electrostatic confinement (IEC) devices plays an important role in the atomic and molecular physics processes in the device and in the resulting energy spectrum of the fast ions and the neutron production rate. A zero dimensional rate equation model for the ion species composition in the source region of IEC devices is presented and compared with experimental measurements on the Wisconsin IEC device [J. F. Santarius, G. L. Kulcinski, R. P. Ashley et al., Fusion Sci. Tech. 47, 1238 (2005)]. The ion species composition is measured using an ion acoustic wave diagnostic; the results are in good agreement with the theoretical predictions. Both the theory and the experimental results show that D3+ ions are the majority species in the source region.