Abstract

We describe here the composition and thermal structure of the upper troposphere and lower stratosphere during a penetrating mesoscale convective complex (MCC) event that occurred in southern China on 8 June 2009. Our results are based on satellite observations and Weather Research and Forecasting model simulations. Ice-rich and ozone-poor air reached as high as 17 km. The air was −5°C colder inside the mature MCC than outside at the first cold-point tropopause near 17 km, −2°C colder inside the mature MCC than outside at the second cold-point tropopause, and 3°C warmer inside the mature MCC than outside between the two cold-point tropopauses. Corresponding to the temperature structure, there were two lower water vapor contents inside the MCC than outside near 17 km and 19 km while there was a higher water vapor content inside the MCC than outside near 18 km.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.