Abstract

BackgroundThe use of right-censored composite endpoints, such as progression-free survival, has been questioned in haemato-oncology trials due to potential bias in estimated treatment effect. This may impact the accuracy of health technology evaluations. We hypothesized that there is heterogeneity and potential sources of bias in the reporting of composite endpoints to health technology assessment (HTA) bodies. MethodsWe reviewed the submissions for reimbursement of oncology drugs in 2021 and 2022 that used a composite endpoint in the pivotal trial, after appraisal by the French HTA body. The retrieved information included the clinical study report, protocol, and statistical analysis plan submitted by the industry. All events of the composite endpoint and all causes of censored observations were measured. The design characteristics and treatment effect estimates were recorded. FindingsSeventy-six submissions were selected, including seven without a right-censored endpoint and four evaluating associations, resulting in 65 analysed records: 17 for haematological and 48 for solid tumours. Out these 65 submissions, 47 (72·3%) used a randomized controlled design, and 18 (27·7%) a non-comparative design. The most frequently used composite endpoint was progression-free survival, used in 54 (83·1%) of the submissions. Censoring was possibly informative in 51 (92·7%) cases, mostly due to the onset of new treatment (44/51, 86·3%) and/or discontinuation of follow-up (33/51, 64·7%). In contrast, 38 (58·5%) trials reported a quantification of censored observations, with only 12/51 (23·5%) quantifying the informative ones. The estimated treatment effect on the composite outcome increased with the amount of censoring, suggesting a higher benefit of the drug, but remained below that on survival with poor evidence of surrogacy (R-squared=0·23). InterpretationClinical study reports should be improved in terms of reporting censoring, while stakeholders should be aware of this potential source of bias. At a minimum, sensitivity analysis that ignores intercurrent events should be requested.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.