Abstract

This paper presents experimental results of 44 composite beam structures tested under static and fatigue loads. While designing the specimens, variables considered included: (1) the number of shear studs; (2) reinforcing method (deformed bars versus welded wire fabric); and (3) load levels and load ranges for fatigue tests. Results show that (1) cracks were initiated in the concrete slab; (2) propagation and connection of cracks led all specimens to fail; (3) the shear studs become stressed after formation of the cracks; (4) crushing of concrete near the shear studs was observed in some fatigue tests; and (5) the flexural stiffness of the specimens decreased through fatigue tests. The specimens containing wire mesh are superior to those containing steel bars. Moreover, no practical difference in structural behavior was found between the full composite and the 80% composite specimens.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.