This paper investigates the development of the wavelet neural network with local recurrent structure and its application to fault detection and isolation (FDI) of components of a dynamic process. Hybrid learning based on orthogonal least-squares and the steepest-descent method, is used to train the proposed neural network. The experimental case study concerns the component fault diagnosis of a three-tank system. A neural simplified observer scheme is used to generate the residuals (symptoms) in the form of one step-ahead prediction errors. These are further analysed by a neural classifier in order to take the appropriate decision regarding the actual behaviour of the process.