Respirators must be properly used to be effective. In an experimental protocol, 145 subjects were trained and then observed donning and doffing respirators. Filtering facepiece and dual cartridge half face mask types were studied. Subjects were then tested for knowledge and for proper performance using video recording analysis. Knowledge tests showed adequate learning, but performance was often poor. Inspection, strap tension (half mask), seal checking, and avoiding mask contact during doffing were particularly problematic. Mask positioning was generally well done. Correlation between knowledge and performance for specific items was generally poor, although there was a weak correlation between overall knowledge and overall performance (rho = 0.32) for the half mask users. Actual unprompted performance as well as knowledge and fit-testing should be assessed for user certification. Respirator design approval should consider users' ability to learn proper technique.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.