Abstract

A collaborative determination of the major components of silver brazing filler metals (Ag–Cu–Zn–Cd, Ag–Cu–Zn–Ni, and Ag–Cu–Zn–Sn alloys) by inductively coupled plasma atomic emission spectrometry (ICP-AES) was conducted. The classical wet methods of gravimetry and titrimetry were also investigated for comparison, most of which are provided by Japanese Industrial Standards (JIS). Results of instrumental and classical analyses using a simple dissolution procedure with nitric acid showed excellent trueness and precision amongst all laboratories and for all alloys except those containing tin. The tin-containing alloy had to be dissolved, suppressing precipitation of the sparingly soluble hydrous tin(IV) oxide. Dissolution with mixtures of nitric and sulfuric acid gave the most satisfactory results without precipitation, thus enabling an accurate determination that favourably compared to the classical wet results. Finally we have evaluated the ICP-AES method and a hybrid method with gravimetry and ICP-AES according to the precision required, and found them to be suitable for standardization.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call