Abstract

Central venous catheters are essential for management of hospitalized patients, but their insertion is subject to complications that can make them unusable and/or cause patient morbidity. There are few data on the incidence of these complications and the variables associated with these outcomes in Brazil. To determine the incidence of mechanical complications and failures of short stay central venous catheters fitted by the vascular surgery service at a teaching hospital and identify variables associated with their occurrence. This was a prospective cohort of 73 attempts to fit patients with a central venous catheter performed by the vascular surgery service at a teaching hospital from July to October of 2022. Mechanical complications occurred in 12 cannulation attempts (16.44%) and there were 10 failures (13.70%). The factors associated with mechanical complications were less experienced operators (p < 0.001), less specialized operators (p = 0.014), a failed attempt prior to requesting help from the vascular surgery service (p = 0.008), and presence of at least two criteria for difficulty (p = 0.007). The local incidence of mechanical complications and central venous cannulation failures was similar to rates described in the international literature, but higher than rates in other Brazilian studies. The results suggest that the degree of experience of the person fitting the catheter, history of a failed prior attempt, and presence of at least two criteria for difficulty identified before the procedure were associated with worse outcomes.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call