Abstract

BackgroundBiological reconstruction after tumor resection is significant for restoration of limb integrality. However, it is unclear what risk factors influence mechanical complications of patients after extremity sarcoma resection and biological reconstruction. The objective of study was (1) to compare complications between patients receiving inactivated autograft and allograft, (2) to analyze influence of graft type, nonunion and fixation method on mechanical complications for patients after biological reconstruction. HypothesisWe hypothesized allograft, nonunion and fixation method influence occurrence of mechanical complications after biological reconstruction. Materials and methodsWe retrospectively reviewed 71 patients with sarcomas at the extremity receiving biological reconstruction from January 1999 to November 2015. Eight patients were lost at last follow-up. Sixty-three patients with complete clinical data were recruited into the present study. There were 32 males and 31 females with a mean age of 20.5±14.9 yrs (median, 17 yrs; range, 2–72 yrs). Sixty-one cases had tumors at lower extremity and two at upper extremity. Histological diagnosis was confirmed as forty-five with osteosarcoma, thirteen with Ewing sarcoma and five with chondrosarcoma. ResultsForty-four patients were free of disease, sixteen died of disease and three lived with pulmonary metastasis at last follow-up. Twenty-one out of 63 patients (33.3%) had local recurrence requiring surgical treatment. Reconstruction choice (mechanical complications rates were 38.9% for allograft (14/36) versus 14.8% inactivated autograft (4/27)) and nonunion occurrence (yes 58.8% (10/17); no 17.4% (8/46)) had the close relationship with mechanical complication in the univariate analysis. The multivariate analysis revealed fixation method (p=0.041) and nonunion (p=0.008) were prognostic factors for mechanical complication of sarcoma resection and biological reconstruction at the extremity. Fourteen of 36 patients receiving massive allograft had a second surgery due to mechanical complication compared to 4 of 27 patients with massive inactivated autograft [38.9%, 14/36 vs. 14.8%, 4/27 (p=0.05)]. Time to union for diaphysis and metaphysis was not significantly different between allograft and inactivated autograft groups. DiscussionPatients receiving massive allograft are prone to suffer from the mechanical complications. Extramedullary plate and nonunion have the tendency of increasing occurrence of mechanical complications of biological reconstruction. Level of EvidenceIV; retrospective study.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.