We investigated the complications and frequency of hook plate fixation in patients with shoulder trauma. We reviewed 216 cases of hook plate fixation use at our hospital between January 2010 and May 2020. Finally, we included 76 cases of acute distal clavicle fracture (DCF) and 84 cases of acute acromioclavicular joint dislocation (ACD). We investigated all complications after hook plate use, bony union in the DCF group, and reduction loss in the ACD group. We defined painful shoulder stiffness (PSS) as aggravating resting pain with stiff shoulder, and pain on shoulder elevation (PSE) as continued shoulder pain on elevation without PSS before plate removal. PSS was managed with intra-articular steroid injections or manipulation with or without arthroscopic capsular release (ACR). PSS occurred in 36 and 33 cases of DCF and ACD, respectively. PSE occurred in 17 of 76 fractures and 13 of 84 dislocations. However, no iatrogenic rotator cuff injury was verified by magnetic resonance imaging in patients with PSS or PSE. Subacromial erosion in patients with hook plate fixation should be considered a sequela and not a complication because it is unavoidable in surgery with an AO-type hook plate. The most common complication was PSS, followed by PSE.

Highlights

  • We investigated the complications and frequency of hook plate fixation in patients with shoulder trauma

  • In order to match the hook part of the metal plate with the lower edge of the acromion as much as possible, the special fluoroscopic view technique we developed was utilized for the best fit between the hook and the acromion, which was helpful in reducing the inevitable acromial erosion [27]

  • Some patients with painful shoulder stiffness (PSS) improved with intra-articular steroid injection before plate removal, and all other patients improved with manipulation or arthroscopic capsular release (ACR) during plate removal

Read more

Summary

Introduction

We investigated the complications and frequency of hook plate fixation in patients with shoulder trauma. We reviewed 216 cases of hook plate fixation use at our hospital between January. We included 76 cases of acute distal clavicle fracture (DCF) and 84 cases of acute acromioclavicular joint dislocation (ACD). We investigated all complications after hook plate use, bony union in the DCF group, and reduction loss in the ACD group. As continued shoulder pain on elevation without PSS before plate removal. PSS occurred in 36 and 33 cases of DCF and ACD, respectively. PSE occurred in 17 of 76 fractures and 13 of 84 dislocations. Subacromial erosion in patients with hook plate fixation should be considered a sequela and not a complication because it is unavoidable in surgery with an AO-type hook plate.

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call