Abstract
To examine the proportion and rate of central venous access device failure and complications across central venous access device types in adult intensive care. A systematic search was undertaken in the electronic databases Cochrane Central Register of Controlled Trials, Embase, U.S. National Library of Medicine National Institutes of Health, and Cumulative Index to Nursing and Allied Health in September 2017. Included studies were of observational (prospective and retrospective) or interventional design and reported central venous access device failure and complications in adult ICU settings. Studies were excluded if they were published prior to November 2006 or not reported in English. Two reviewers independently screened articles, assessed eligibility, extracted data, and assessed risk of bias. Data were extracted on the primary outcome, central venous access device failure, and secondary outcomes: central venous access device complications (central line-associated bloodstream infection, catheter-related bloodstream infection, catheter-related thrombosis, occlusion, catheter removal due to suspected infection, dislodgement, breakage, and local infection). Patient and device data and study details to assess the study quality were also extracted. A total of 63 studies involving 50,000 central venous access devices (396,951 catheter days) were included. Central venous access device failure was 5% (95% CI, 3-6%), with the highest rates and proportion of failure in hemodialysis catheters. Overall central line-associated bloodstream infection rate was 4.59 per 1,000 catheter days (95% CI, 2.31-6.86), with the highest rate in nontunneled central venous access devices. Removal of central venous access device due to suspected infection was high (17%; 20.4 per 1,000 catheter days; 95% CI, 15.7-25.2). Central venous access device complications and device failure is a prevalent and significant problem in the adult ICU, leading to substantial patient harm and increased healthcare costs. The high proportion of central venous access devices removed due to suspicion of infection, despite low overall central line-associated bloodstream infection and catheter-related bloodstream infection rates, indicates a need for robust practice guidelines to inform decision-making surrounding removal of central venous access devices suspected of infection.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.