Abstract

A Nebulizer Chronolog, a portable device that houses a standard nebulizer canister, was used in a unique method to measure compliance with aerosolized medication. Each actuation is tabulated to within 4 minutes of the actual time of usage and can subsequently be displayed in a day-hour-minute format. Of the 19 patients studied for 12 weeks with a cromolyn-like agent, appropriate usage four times a day ranged from 4.3% to 94.8%. Underusage exceeded overusage and ranged from 5.2% to 95% of the study days. Younger subjects and male subjects were less likely to use the aerosol appropriately. Patients failed to write the truth in their diaries with overreporting of appropriate usage more than 50% of the times. Lack of compliance with aerosolized medication represents an important medical issue for the physicians caring for patients with asthma. The Nebulizer Chronolog elicits new insight into the disparity between reported and observed compliance.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.