Abstract
We proposed and experimentally demonstrated a delay-match sampling method to measure and compensate the laser phase error in optical frequency-domain reflectometry system. By using the error signal extracted from a simple auxiliary Mach-Zehnder interferometer with only a 10-ns delay, the laser phase error is effectively compensated. Considerable improvement is achieved in spatial resolution from 200 m to 7 cm at a measurement distance over 10 times the round-trip laser coherence length.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.