Abstract
A longitudinal coupled-bunch (CB) instability was encountered in the 7-GeV storage ring. This instability was found to depend on the bunch fill pattern as well as on the beam intensity. The beam spectrum exhibited a coupled-bunch signature, which could be reproduced by an analytical model. The oscillations were also observed on a horizontal photon monitor. The beam fluctuations exhibited two periodicities, which were found to be correlated with the rf cavity temperatures. This correlation is consistent with the measured temperature dependence of the higher-order mode (HOM) frequencies. The HOM impedance drives the beam when brought into resonance with the CB mode by the temperature variation. Increasing the inlet cavity water temperature suppressed the instability. The experimental results are compared to an analytical model which characterizes the fill-pattern dependence. Studies to identify the offending HOMs are also presented.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.