Abstract

The straightness measurement systematic errors induced by error crosstalk, fabrication and installation deviation of optical element, measurement sensitivity variation, and the Abbe error in six degree-of-freedom simultaneous measurement system are analyzed in detail in this paper. Models for compensating these systematic errors were established and verified through a series of comparison experiments with the Automated Precision Inc. (API) 5D measurement system, and the experimental results showed that the maximum deviation in straightness error measurement could be reduced from 6.4 to 0.9μm in the x-direction, and 8.8 to 0.8μm in the y-direction, after the compensation.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call