Abstract

BackgroundAs a near-physiological pacing innovation, left bundle branch area pacing (LBBAP) has drawn much attention recently. This study was aimed to investigate the electrophysiological characteristics, unipolar/bipolar pacing parameters and mid- to long-term effects and safety of three different pacing methods and identify possible predictors of adverse left ventricular remodeling.MethodsNinety-two patients were divided into the LBBAP group, right ventricular septal pacing (RVSP) group and right ventricular apical pacing (RVAP) group. Baseline information, electrophysiological, pacing and echocardiographic parameters were collected.ResultsThe three pacing methods were performed with a similar high success rate. The paced QRSd was significantly different among the LBBAP, RVSP and RVAP groups (105.93 ± 15.85 ms vs. 143.63 ± 14.71 ms vs. 155.39 ± 14.17 ms, p < 0.01). The stimulus to left ventricular activation time (Sti-LVAT) was the shortest in the LBBAP group, followed by the RVSP and RVAP groups (72.80 ± 12.07 ms vs. 86.29 ± 8.71 ms vs. 94.14 ± 10.14 ms, p < 0.001). LBBAP had a significantly lower tip impedance during the procedure and 3-month follow up as compared to RVSP and RVAP (p < 0.001). Higher bipolar captured thresholds were observed in LBBAP during the procedure (p < 0.001). Compared to the baseline values, there was a greater reduction in left ventricular end-diastolic dimension (LVEDD) in the LBBAP group (p = 0.046) and a significant enlargement in LVEDD in the RVAP group (p = 0.008). Multiple regression analysis revealed that the Sti-LVAT was a significant predictor of LVEDD at 12 months post-procedure. At the 24-h post-procedure, significant elevations were observed in the cTnI levels in LBBAP (p < 0.001) and RVSP (p < 0.05). More transient RBB injury was observed in LBBAP. But no significant difference was found in cardiac composite endpoints among three groups (p > 0.05).ConclusionsLBBAP demonstrated a stable captured threshold, a low tip impedance and a high R-wave amplitude during the 12-month follow-up. Left ventricular remodeling was improved at 12 months post-procedure through LBBAP. The Sti-LVAT was a significant predictor of left ventricular remodeling. LBBAP demonstrated its feasibility, effectiveness, safety and some beneficial electrophysiological characteristics during this mid- to long-term follow-up, which should be confirmed by further studies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.