Abstract

Breakdown voltages in uniform and quasi-uniform field gaps are sensitive to the presence of small protrusion on the electrode surface in SF6 at high pressures. The aim of the present work is to study direct breakdown and corona stabilized breakdown for the transitive region from uniform to nonuniform gap in dry air and SF6 at low pressures up to a critical pressure when direct breakdown takes place by a leader discharge crossing the gap in SF6. In a parallel-plane gap with a variable-height protrusion subjected to the dc voltage, corona onset voltage is remarkably controlled by the protrusion height. The present electrode arrangement has the advantage of directly measuring the minimum critical guiding field strength for the propagation of a streamer discharge at corona onset. The experimental observations have been explained qualitatively on the basis of a streamer model and precise electric field calculations of gap.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call