Abstract

This study aimed to compare the outcomes of the AUS and an adjustable male sling (ATOMSTM). It was a retrospective observational cohort study with two arms. Propensity score matching (PSM) was performed in order to limit selection bias and, consequently, a comparison between groups in terms of functional outcomes (24 h pad test and perception of improvement questionnaires), complications (overall complications, high-grade complications, reinterventions and explantations) and device survival was performed. 49 patients in both arms were included. The baseline characteristics were similar between the groups. The mean follow up was 43 ± 35 months. Dryness was achieved in 22 patients (44.9%) in the AUS group and 11 (22.5%) in the sling group (p = 0.03). A total of 40 patients declared themselves well improved in the sling group (81%), while 35 (71%) declared the same in the AUS group (p = 0.78). The AUS was associated with more high-grade complications, reinterventions and explantations than the ATOMSTM. Survival at 60 months was 82 ± 9% in the sling group and 67 ± 7% in the AUS group (p = 0.03). While the AUS may be characterized by a higher dry rate, it has an increased risk of high-grade complications and reinterventions. It is proposed that the ATOMS prosthesis can be successfully used for patients who require a less invasive procedure that maintains good functional outcomes.