Abstract

CFD technique is often employed to simulate and optimize air duct design, but the corresponding experiment validation in metro vehicle is rare. By taking an independent metro vehicle duct as research object in this paper, supply air through air duct is simulated and compared with the actual test results from the angle of supply air velocity at each outlet and supply air volume through several outlets of air duct. The results show that the relative deviation of simulation and test value of air velocity at most of the outlets are within or near ±20%, which is acceptable for the engineering applications. Moreover, the ratio of supply air volume through several outlets to the corresponding total supply air volume through main air duct or flat duct in the case of simulation is consistent with that in the case of experiment. It can be concluded that numerical simulation method is effective and reliable in air duct optimization design of metro vehicle.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.