Abstract

This study has compared the equivalent external pressure coefficients, (GCpf)eq, with 6 wind load provisions and wind tunnel test data. The wind load provisions are the ASCE 7-10, NBCC 2010, AS/NZS 2011, EN 2005, AIJ 2004 and KBC 2009. Experiment data on low-rise building have been obtained at the University of Western Ontario (UWO) to contribute to the NIST aerodynamic database [. For the experiment, a model with 1:12 of roof slope and 4.9 and 12.2m of eave height was used under open terrain conditions (See also Ref. [). (GCpf)eq was re-normalized based on the external pressure coefficients, GCpf, of ASCE 7-10. When compared to (GCpf)eq of the experiment data with 4.9m of eave height, consequently, ASCE 7-10 (81%), NBCC 2010 (84%), AS/NZS 2011 (70%), AIJ 2004 (68%) and KBC 2009 (53%) were all underestimated. Among them, KBC 2009 reveals the lowest value. On the contrary, EN2005 was overestimated with 122%. When the eave height was 12.2m, in addition, the same pattern was observed in most codes. EN2005 was slightly overestimated with 115%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.