Abstract

Spatial information on urban forest canopy height (FCH) is fundamental for urban forest monitoring and assisting urban planning and management. Traditionally, ground-based canopy height measurements are time-consuming and laborious, making it challenging for periodic inventory of urban FCH at crown level. Airborne-light detection and ranging (LiDAR) sensor can efficiently measure crown-level FCH; however, the high cost of airborne-LiDAR data collection over large scales hinders its wide applications at a high temporal resolution. Previous studies have shown that in some cases, the Unmanned Aerial Vehicle (UAV)-digital aerial photogrammetry (DAP) approach (i.e., UAV-based structure from motion algorithm) is equivalent to or even outperform airborne-LiDAR in measuring forest structure, but few studies have evaluated their performances in measuring FCH in more complex urban environment, across non-ground coverage (including both canopy and building coverage) and topographical slope gradients. Also, the contribution of multi-angle measurement technique from UAV-DAP to FCH estimation accuracy has rarely been explored in the urban environment. Here, we compared the performances of UAV-LiDAR and UAV-DAP approaches on measuring thousands of crown-level FCH at different non-ground coverage and topographical slope areas in an urban environment. Specifically, UAV-LiDAR-based spatial measurements of crown-level FCH were used as the reference after ground-based validation (R2 = 0.88, RMSE = 2.36 m). The accuracy of UAV-DAP approach with/without multi-angle measurement in different non-ground coverage and topographical slope areas were then analyzed. The results showed that although the DAP multi-angle-based approach can improve the accuracy of spatial measurement for crown-level FCH in some cases, non-ground coverage (including both canopy and building coverage) was still the main factor affecting the broad applications of DAP approach in measuring urban FCH: at areas where non-ground coverage < 0.95, no matter how topographical slope varied, the accuracy of DAP approach was high (R2 = 0.86∼0.94, RMSE = 1.56∼2.93 m); at areas where non-ground coverage > 0.95, except for the case of flat areas (i.e., topographical slope <= 2°), the accuracy of DAP was poor (R2 = 0.20, RMSE = 12.34 m). However, using LiDAR-digital terrain model (DTM) instead of DAP-DTM, at areas where non-ground coverage > 0.95, can significantly improve the accuracy of UAV-DAP approach in measuring crown-level FCH (R2 = 0.91, RMSE =1.61 m). Our study thus provides a complete guidance on the usage of cost-effective UAV-DAP approach for measuring crown-level FCH in the urban environment, which will be helpful for precise urban forest management and improving the efficiency of urban environmental planning.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call