Abstract

. A study of the leaching losses of nitrate under urine patches in irrigated and non-irrigated dairy pastures in the South East of South Australia was undertaken with repacked and monolith lysimeters 1 m deep, and with monolith lysimeters 150, 300 and 450 mm deep. The aim was to quantify differences in measurements of drainage and nitrogen fluxes for these different lysimeters. Drainage of water and N flux were found to vary significantly between types and depths of lysimeters. Drainage volumes in repacked lysimeters were 78% and 33% more than in monolith lysimeters in irrigated and non-irrigated paddocks, and N fluxes were 5 and 3 times higher in repacked lysimeters respectively. The results indicate that lysimeter estimates of recharge rates and N fluxes to water tables are best determined by leaching studies which are longer term, and use deep monolith lysimeters. Shorter term studies and the use of shallow or repacked lysimeters have potential to distort conclusions.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call