Abstract

The current study compares two vacuum system designs for the Iranian Light Source Facility (ILSF) storage ring: conventional vacuum system design with stainless-steel vacuum chambers that are pumped by Non-Evaporable Getter (NEG) cartridges and ion pumps. In this design, all synchrotron radiation is absorbed by the local photon absorbers. In the second design, the water-cooled copper tubes that are coated with NEG materials are used as the vacuum chambers. This study will illustrate the advantages of using the NEG-coated vacuum chambers over the conventional design with the stainless-steel chambers. Since the two designs for ILSF are now completed, some of the details of this comparison might be interesting to other light sources, especially those that have plans to upgrade to a 4th generation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.