Abstract

This paper investigates two diagnosis methods based on switching voltage pattern for IGBTs open-circuit faults in voltage-source inverters. One is based on bridge arm pole voltage, and the other is based on bridge arm line voltage. With extra simple circuit, these two diagnosis methods can detect and identify single and multiple open-circuit faults of the inverter IGBTs effectively. The comparison of diagnosis time and anti-interference feature between these two methods has been presented. The simulation results are carried out to show the effectiveness and differences of these two methods.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.