Abstract

AbstractIn comparing the similarity between time, frequency, and phase measurements as used in the induced polarization method of geophysical prospecting, parameters must first be defined and the basis for comparison established. The conditions for mathematical equivalence then follow in a natural sequence. Laboratory measurements are made on a variety of rock samples to indicate the type of comparison and correlation expected from field measurements.Results indicate that frequency domain and phase measurements are equivalent, but two frequency domain measurements are needed to produce the same amount of polarization information as a single phase measurement. Frequency and time domain measurements will be similar but never equivalent due to the basic differences in their respective parameter definitions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.