Abstract

BackgroundIn the current study, we aimed to evaluate the accuracy of indirect bonding by either three-dimensional (3D) printing guides or double-layer guide plates. The results may serve as a clinical reference for bracket placements.MethodsIn total, 140 teeth were collected and arranged into five pairs of full dentition. The marking points were labeled on the buccal/labial surface of the crown in these orthodontic study models. (1) 3D printing guide: A digital profile was generated using an intraoral scanner. Two types of indirect bonding guide, namely the whole denture type and the single tooth type, were designed with the 3Shape TRIOS® Standard intraoral scanner and fabricated using 3D printing technology. (2) Double-layer guide plate: A working model was obtained by replicating the experimental models, and the double-layer guide plate was then made of the inner layer soft film (1.0 mm thickness) and the outer layer hard film (0.6 mm or 0.8 mm thickness). Brackets were transferred from working models to study models by the indirect bonding trays. We measured and analyzed the distance between marking points and bracket placement. Statistical analysis was done using SPSS 20.0 software. The accuracy of indirect bonding between 3D printing guide and double-layer guide plate was compared using paired t-test.ResultsAccording to our data, there was a significant difference between the 0.6 mm group and 0.8 mm group when the brackets were indirectly adhered using double-layer guide plates (p = 0.036). However, no statistical significance in bracket positioning accuracy was revealed between two types of 3D printing guide (p = 0.078), as well as between the 3D printing guide group and the 0.6 mm double-layer guide plate group (p = 0.069).ConclusionsWhen applying double-layer guide plates for indirect bonding, the 0.6 mm group is more accurate than the 0.8 mm group. When utilizing 3D printing guides for indirect bonding, whole denture type is more accessible than single tooth type but with no significant difference in accuracy. The accuracy of indirect bonding is comparable when using 3D printing guides (whole denture type) and double-layer guide plates (0.6 mm).

Highlights

  • In the current study, we aimed to evaluate the accuracy of indirect bonding by either threedimensional (3D) printing guides or double-layer guide plates

  • When applying double-layer guide plates for indirect bonding, the 0.6 mm group is more accurate than the 0.8 mm group

  • When utilizing 3D printing guides for indirect bonding, whole denture type is more accessible than single tooth type but with no significant difference in accuracy

Read more

Summary

Introduction

We aimed to evaluate the accuracy of indirect bonding by either threedimensional (3D) printing guides or double-layer guide plates. Orthodontic brackets can be adhered to the tooth surfaces by direct or indirect bonding. Due to the presence of saliva and some inaccessible tooth positions, direct bonding usually takes longer chair-side time and lacks accuracy [2]. To optimize the accuracy of bracket positioning, indirect bonding technique was proposed by Silverman and Cohen in 1972 and since became a popular alternative [1, 3]. After obtaining patients’ orthodontic models, brackets are bonded to the study models in the laboratory stage, and placed on tooth surfaces integrally with the aid of a customized transfer tray in the clinical stage [5, 6]. Though the chair-side time is significantly reduced, there are considerable laboratory-associated expenses when indirect bonding is chosen [7]

Objectives
Methods
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.