Abstract

Study Design Radiological cohort study.PurposeThe options of posteriorly stabilizing C7 vertebra include using lateral mass, pedicle or lamina, as bony anchors. The current study is a computed tomography (CT)-based morphometric analysis of C7 vertebra of 100 Indian patients and discusses the feasibility of these different techniques.Overview of LiteratureC7 is a peculiar vertebra with unique anatomy, which poses challenges for each of these fixation modalities. There are no reports available in the literature, which discuss and compare the feasibility of diverse posterior C7 fixation techniques in Indian population.MethodsWe included 100 consecutive cervical spine CT scans of Indian patients performed between July 2016 and September 2016. We excluded CT scans with any significant congenital anomaly or other pathological lesions of C7 and patients with non-Indian ethnicity. Regarding screw placement, we assessed and studied various dimensions of the C7 lateral mass, pedicles, and laminae in relevant sections.ResultsThe mean age of our patients was 49.5±16.1 years. We included 56 male and 44 female patients. The mean anteroposterior and mediolateral dimensions of the lateral mass were 11.38±1.76 and 12.91±1.82 mm, respectively. The mean length of the lateral mass screw (Magerl technique) was 12.17±1.9 mm; 92% of patients could accommodate a lateral mass screw at least 10-mm long (unicortical), whereas 48% could accommodate a screw (unicortical) longer than 12 mm. Foramen transversarium was found in 30.5% of lateral masses. The mean outer and inner cortical widths of the pedicles were 6.5±0.71 mm and 3.72±0.61 mm, respectively. Approximately 58% of pedicles could accommodate 3.5-mm screws (based on the inner cortical pedicle width). The outer cortical and inner cortical widths of the laminae were 6.21±1.2 mm and 3.23±0.9 mm, respectively. Subsequently, 37% of the laminae could accommodate 3.5-mm screws. The mean angle of intralaminar screw trajectory was 50.7°±5.1°, and the mean length of the intralaminar screw was 32.6±3.05 mm. In addition, 96.4% and 60.7% of male patients could accommodate lateral mass screws longer than 10 mm and 12 mm, respectively. However, only 86.4% and 31.8% of female patients could accommodate 10- and 12-mm long lateral mass screws, respectively. Furthermore, 75% of male patients and 36% of female patients had pedicles that could accommodate 3.5-mm diameter screws, and 48.2% of male patients had laminae that could accommodate 3.5-mm screws; however, only 22.7% of female patients could accommodate 3.5-mm laminar screws.Conclusions Based on our CT-guided morphometric analysis, 92% and 48% of Indian patients could accommodate at least 10- and 12-mm long lateral mass screws, and 58% of pedicles and 37% of laminae could accommodate 3.5-mm screws. Thus, lateral mass screws (between 10- and 12-mm long) seem to be the safest feasible option for C7 fixation. In case of the need for an alternative mode of stabilization (pedicle or intralaminar screw), particularly in female patients, careful preoperative planning with a CT scan is of utmost importance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.