Abstract

The capacitance of a single electrode is usually measured by injecting a current to the electrode and measuring the resultant voltage on the electrode. In this case, a voltage-controlled current source with a high bandwidth is needed because the impedance is inversely proportional to the excitation frequency. In this design note, three different current sources are discussed: (1) the Howland current source, (2) a modified Howland current source, and (3) a dual op-amp current source. The principle and dynamic performances are presented and compared. Simulation and experimental results show that although the Howland current source has the lowest (i.e., worst) output impedance, its output is the most stable among the three current sources when the frequency changes. Therefore, it is suitable for single-electrode capacitance measurement. Initial tests have proven the feasibility of single-electrode capacitance sensor with the Howland current source.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call