Abstract

Three commercially available diagnostic assays for the detection of antibodies to varicella-zoster virus were evaluated to determine which would be the most suitable for our clinical laboratory. Three different methods were examined: an enzyme-linked immunosorbent assay (ELISA), latex agglutination (LA), and an indirect fluorescent-antibody technique. For the 141 serum specimens tested, the ELISA had an agreement of 90.1% and LA had an agreement of 92.2% with the indirect immunofluorescent-antibody technique. The ELISA had a lower sensitivity (85.6%) than LA (100.0%), but suffered from a low specificity (78.4%) compared with the ELISA (98.0%).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.