Abstract

Abstract The enthalpy of mixing of the ternary Cu –Sn–Zn system was measured using a Calvet-type calorimeter. The investigations were carried out along the three cross sections Cu : Sn = 1 : 2, 1 : 1, and 2 : 1. Zn was added in the concentration range between 0 and 50 at.%. The calorimetric results were compared with EMF data investigated in an earlier work by Peng and Mikula [1]. The results of the calorimetric measurements show very good agreement in the copper-rich region, compared with the EMF measurements, but in the Cu : Sn = 1 : 2 cross section the results do not fit perfectly. The difference between both measuring methods was at the most ΔH = 300 J/mol at the cross section Cu : Sn = 1 : 1 and ΔH = 150 J/mol at the Cu : Sn = 2 : 1 cross section.