Abstract

Guided apicoectomy performed with 3D-printed polymer-based static surgical guides is an emerging trend in endodontic surgery. Static-guided apicoectomy is carried out with either a drill or a trephine. The aim of this in vitro study was to assess the accuracy of osteotomy and apicoectomy performed through a polymer guide, with both drill and trephine, and to compare the accuracy achievable with the two instruments. Six plaster models of a maxilla master model with extracted human maxillary teeth in polymethyl-methacrylate resin were used. The modeled osteotomies were performed in these. The master model was CBCT-scanned, and digital surgical plans were prepared, based on which the surgical guides were printed. The plans contained both drill and trephine apicoectomies. Digital three-dimensional position analysis was performed with dedicated algorithms. A total of 39 drill and 47 trephine osteotomies were analyzed. A statistically significant difference between the two instruments was found only in the global deviation of the distal endpoint, indicating lower deviation for the trephine procedure (1.53 mm vs. 1.31 mm, p = 0.038). Nevertheless, from a clinical perspective, this distinction is inconsequential. The results suggest that, for all practical purposes, the two approaches to apicoectomy allow the same level of accuracy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.