Abstract

The sulforhodamine B (SRB) protein stain assay was compared with the tetrazolium (MTT) colorimetric assay for in vitro chemosensitivity testing of various human tumour cell lines. The SRB assay provided a better linearity with cell number and a higher sensitivity, and its staining was not cell-line dependent. In contrast to the MTT assay, the SRB assay stained recently lysed cells. Cell debris, however, was not stained by SRB and therefore the drug sensitivity data were not affected.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.