BackgroundEfforts to improve the performance of rotary NiTi instruments by enhancing the properties of NiTi alloy, or their manufacturing processes rather than changes in instrument geometries have been reported. The aim of this study was to compare in-vitro the shaping ability of three different rotary nickel-titanium instruments produced by different manufacturing methods.MethodsThirty simulated root canals with a curvature of 35˚ in resin blocks were prepared with three different rotary NiTi systems: AK- AlphaKite (Gebr. Brasseler, Germany), GTX- GT® Series X (Dentsply, Germany) and TF- Twisted Files (SybronEndo, USA).The canals were prepared according to the manufacturers’ instructions. Pre- and post-instrumentation images were recorded and assessment of canal curvature modifications was carried out with an image analysis program (GSA, Germany).The preparation time and incidence of procedural errors were recorded. Instruments were evaluated under a microscope with 15 × magnifications (Carl Zeiss OPMI Pro Ergo, Germany) for signs of deformation. The Data were statistically analyzed using SPSS (Wilcoxon and Mann–Whitney U-tests, at a confidence interval of 95%).ResultsLess canal transportation was produced by TF apically, although the difference among the groups was not statistically significant. GTX removed the greatest amount of resin from the middle and coronal parts of the canal and the difference among the groups was statistically significant (p < 0.05). The shortest preparation time was registered with TF (444 s) and the longest with GTX (714 s), the difference among the groups was statistically significant (p < 0.05). During the preparation of the canals no instrument fractured. Eleven instruments of TF and one of AK were deformed.ConclusionUnder the conditions of this study, all rotary NiTi instruments maintained the working length and prepared a well-shaped root canal. The least canal transportation was produced by AK. GTX displayed the greatest cutting efficiency. TF prepared the canals faster than the other two systems.
Highlights
Efforts to improve the performance of rotary NiTi instruments by enhancing the properties of NiTi alloy, or their manufacturing processes rather than changes in instrument geometries have been reported
* Correspondence: bahattab@med.uni-rostock.de Department of Operative Dentistry and Periodontology, Dental School University of Rostock, Strempelstr 13, 18057. It has been two decades since the first NiTi rotary files appeared on the market
For all instruments significantly more material was removed on the outer wall than the inner wall in the apical and coronal parts of the canal except in segments 2 and 4 of Twisted Files (TF) and GTX groups respectively (p < 0.05)
Summary
Efforts to improve the performance of rotary NiTi instruments by enhancing the properties of NiTi alloy, or their manufacturing processes rather than changes in instrument geometries have been reported. The aim of this study was to compare in-vitro the shaping ability of three different rotary nickel-titanium instruments produced by different manufacturing methods. It has been two decades since the first NiTi rotary files appeared on the market. Constant helical angles and a constant blade pitch which is the distance between two cutting edges can be adapted [5]. By varying these two parameters along the blade length, the cutting action and the ability to remove debris from the blades and prevent screwing can be improved [6]
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.