Abstract

ObjectiveThis study aimed to investigate the strength of a novel micro‐dynamic pedicle screw by comparing it to the traditional pedicle screw.MethodsForty‐five lumbar vertebrae received a traditional pedicle screw on one side and a micro‐dynamic pedicle screw on the other side as follows (traditional group vs micro‐dynamic group): 15 vertebrae underwent instant pull‐out testing; 15 vertebrae underwent 5000‐cyclic fatigue loading testing; and 15 vertebrae underwent 10,000‐cyclic fatigue loading testing and micro‐computed tomography (micro‐CT) scanning. The peek pull‐out force and normalized peek pull‐out force after instant pull‐out testing, 5000‐cyclic and 10,000‐cyclic fatigue loading testing were recorded to estimate the resistance of two types of screws. Bone mineral density was recorded to investigate the strength of the different screws in osteoporotic patients. And the semidiameter of the screw insertion area on micro‐CT images after fatigue were compared to describe the performance between screw and bone surface.ResultsThe bone mineral density showed a weak correlation with peek pull‐out force (r = 0.252, P = 0.024). The peek pull‐out force of traditional pedicle screw after 10,000‐cyclic fatigue loading were smaller than that of instant pull‐out test in both osteoporotic (P = 0.017) and healthy group (P = 0.029), the peek pull‐out force of micro‐dynamic pedicle screw after 10,000‐cyclic fatigue loading was smaller than that in instant pull‐out test in osteoporotic group (P = 0.033), but no significant difference in healthy group (P = 0.853). The peek pull‐out force in traditional group and micro‐dynamic group underwent instant pull‐out testing (P = 0.485), and pull‐out testing after 5000‐cyclic fatigue loading testing (P = 0.184) did not show significant difference. However, the peek pull‐out force in micro‐dynamic group underwent pull‐test after 10,000‐cyclic fatigue loading testing was significantly greater than that measured in traditional group (P = 0.005). The normalized peek pull‐out force of traditional groups underwent instant pull‐out testing, pull‐out test after 5000‐cyclic and 10,000‐cyclic fatigue loading testing significantly decreased as the number of cycles increased (P < 0.001); meanwhile, the normalized peek pull‐out force of micro‐dynamic groups remained consistent regardless of the number of cycles (P = 0.133). The semidiameter after the fatigue loading test of the traditional screw insertion area was significantly larger than that of the micro‐dynamic screw insertion area (P = 0.013).ConclusionThe novel micro‐dynamic pedicle screw provides stronger fixation stability in high‐cyclic fatigue loading and non‐osteoporotic patients versus the traditional pedicle screw, but similar resistance in low‐cycle fatigue testing and osteoporotic group vs the traditional pedicle screw.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.