Abstract

Objectives: This in-vitro study aimed to evaluate the physical properties of three resin-based root canal sealers, including BETA-RCS, AH26, and Adseal. Materials and Methods: Flowability, film-thickness, solubility, and radiopacity of BETA-RCS, AH26, and Adseal sealers were evaluated according to ISO 6876/2012 specifications. Three samples of each sealer were used to test each of the properties. Results: The results revealed that the flow rate (mm) of BETA-RCS, Adseal, and AH26 were 23.06±1.58, 22.5±4.23, and 21.85±1.71, respectively. Film-thickness values (µm) for BETA-RCS, Adseal, and AH26 sealers were 52.33±2.51, 18.66±0.57, and 52±2, respectively. No significant difference was observed regarding film-thickness between AH26 and BETA-RCS (P>0.05), while Adseal showed significantly lower film-thickness (P˂0.05). The highest and lowest solubility were related to BETA-RCS and Adseal, respectively. However, all sealers had acceptable solubility and radiopacity. Conclusion: The findings of the current study suggested that all three root canal sealers including BETA-RCS, AH26, and Adseal had similar properties based on ISO 6876 standard criteria. As such, they could be viable choices for facilitating effective root canal procedures. Further long-term clinical studies are warranted to assess their performance and success rates in actual endodontic cases.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call