Abstract
In this study, liquid level control in a coupled tank system is realized with PI controllers whose parameters are adapted using fuzzy logic approximation methods. Type-1 fuzzy PI control, interval type-2 fuzzy PI control and classical PI+Feedforward control methods are applied to the tank system in real time for different reference liquid levels. The performances of the controllers are compared in terms of system response parameters such as rise time, settling time and overshoot percentage. In addition, the performance evaluation of the controllers over a certain period of time is also compared by calculating integral-based concepts that express error performance metrics such as integral square error (ISE), integral time square error (ITSE), integral absolute error (IAE) and integral time absolute error (ITAE). The obtained results show that the type-2 fuzzy PI controller shows the best performance, followed by type-1 fuzzy PI control and classical PI+FF controller, respectively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.