Abstract

PurposeThe purpose of this article is to compare the safety of the laryngeal mask airway ProSeal (PLMA) and the streamlined liner of the pharynx airway (SLIPA) during general anesthesia. DesignThis study is a systematic review and meta-analysis. MethodsTwo authors performed searches of Embase, Web of Science, and PubMed to identify clinical trials that compared PLMA and SLIPA in patients receiving general anesthesia. Relative risk (RR) with corresponding 95% confidence intervals (CI) were used to pool the dichotomous data. The mean difference (MD) and the associated 95% CI were applied to pool continuous data. RevMan 5.0 software was used for data analysis. FindingsA total of 15 studies with 1263 patients were included. There was no significant difference between PLMA and SLIPA in the rate of insertion success on the first attempt (RR = 1.02, 95% CI [0.95, 1.09], P = .59), airway sealing pressure (MD = 0.75, 95% CI [−0.09, 1.58], P = .08) and the incidence of a sore throat (RR = 0.85, 95% CI [0.7, 1.04], P = .12). The insertion time of PLMA was shorter than SLIPA (MD = 5.24, 95% CI [0.51, 9.98], P = .03), and the incidence of bloodstaining on the device was lower (RR = 0.72, 95% CI [0.55, 0.94], P = .02). ConclusionsBoth devices have a high rate of insertion success on the first attempt and airway sealing pressure. But PLMA has a shorter insertion time and less incidence of blood staining, which is more advantageous than SLIPA.