Abstract

A comparison of the 10 V Josephson array voltage standard of the Bureau International des Poids et Mesures (BIPM) was made with that of the Hellenic Institute of Metrology (EIM), Greece, in March 2010. For this exercise, the option B of the BIPM.EM-K10.b comparison protocol was applied, in which the BIPM only provides a reference voltage that has to be measured by the EIM using its Josephson voltage standard and its own measuring device. The results of the two participants are in very good agreement and the overall relative standard uncertainty is 2.0 parts in 1010.Main text.To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).