Abstract

This experimental study aimed to compare the internal fit (marginal fit and internal discrepancy) of metal crowns fabricated by traditional casting and digital methods (computer numerically controlled (CNC) milling and three-dimensional [3D] printing). Thirty standard master abutment models were fabricated using a 3D printing technique with digital software. Metal crowns were fabricated by traditional casting, CNC milling, and 3D printing. The silicon replica method was used to measure the marginal and internal fit. A thin layer of low-viscosity polyvinyl siloxane material was placed inside each crown and on the die (like a seat) until the material was set. Replicas were examined at four reference points under a microscope: the central pit (M1), cusp tip (M2), axial wall (M3), and margin (M4). The measured data were analyzed using a one-way analysis of variance (ANOVA) to verify statistical significance, which was set at p < 0.05. In the traditional casting group, the minimum distance measured was at M3 (90.68 ± 14.4 μm) and the maximum distance measured was at M1 (145.12 ± 22 μm). In the milling group, the minimum distance measured was at M3 (71.85 ± 23.69 μm) and the maximum distance measured was at M1 (108.68 ± 10.52 μm). In the 3D printing group, the minimum distance measured was at M3 (100.59 ± 9.26 μm) and the maximum distance measured was at M1 (122.33 ± 7.66 μm). The mean discrepancy for the traditional casting, CNC milling, and 3D printing groups was 120.20, 92.15, and 111.85 μm, respectively, showing significant differences (P < 0.05). All three methods of metal crown fabrication, that is, traditional casting, CNC milling, and 3D printing, had values within the clinically acceptable range. The marginal and internal fit of the crown was far superior in the CNC milling method.

Highlights

  • With the advent of the digital age, dentistry has become increasingly digitalized, combining computer-aided design/manufacturing software (CAD/CAM) and three-dimensional (3D) printing [1]

  • In the traditional casting group, the minimum measured distance was at M3 (90.68 ± 14.4 μm), and the maximum measured distance was at M1 (145.12 ± 22 μm)

  • In the CNC milling group, the minimum measured distance was at M3 (71.85 ± 23.69 μm), and the maximum measured distance was at M1 (108.68 ± 10.52 μm)

Read more

Summary

Introduction

With the advent of the digital age, dentistry has become increasingly digitalized, combining computer-aided design/manufacturing software (CAD/CAM) and three-dimensional (3D) printing [1]. The marginal gap values of various materials, such as zirconia, lithium disilicate, polymethyl methacrylate (a temporary crown material), and traditional casting metal crowns, are approximately 56 [6], 74 [7], 161 [8,9], and 88 μm [10], respectively, which meet clinical standards based on using the dental CAD/CAM system. This experimental study aimed to compare the marginal and internal fit of metallic cobalt and chromium alloys between traditional manually cast crowns and digitally processed crowns (CNC-milled and 3D printed crowns). The null hypothesis is that the internal fit of digitally fabricated crowns is better than those of traditionally fabricated crowns

Materials and methods
Results
Discussion
Conclusions

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.