Abstract

To analyse the magnitude of cylindrical corrections over which cyclotorsion compensation with iris recognition (IR) technology is beneficial during wavefront laser-assisted in situ keratomileusis. A retrospectively comparative case series. Fifty-four eyes that underwent wavefront laser-assisted in situ keratomileusis without IR (non-IR group) and 53 eyes that underwent wavefront laser-assisted in situ keratomileusis with IR (IR group) were recruited. Subgroup analysis based on baseline astigmatism were: a low degree of astigmatism (≥1.00 D to <2.00 D), a moderate degree of astigmatism (≥2.00 D to <3.00 D) and a high degree of astigmatism (≥3.00 D). Vector and non-vector analyses were used for comparison. The mean cylinder was -1.89 ± 0.76 D in the non-IR group and -2.00 ± 0.77 D in the IR group. Postoperatively, 38 eyes (74.50%) in the IR group and 31 eyes (57.50%) in the non-IR group were within ± 0.50 D of the target induced astigmatism vector (P = 0.063). The difference vector was 0.49 ± 0.28 in the IR group and 0.63 ± 0.40 in the non-IR group (P = 0.031). In the analysis of subgroups, the magnitude of error was significantly lower in the moderate IR subgroup than that of the moderate non-IR subgroup (P = 0.034). Furthermore, the moderate IR subgroup had a lower mean difference vector (P = 0.0078) and a greater surgically induced astigmatism (P = 0.036) than those of the moderate non-IR group. Wavefront laser-assisted in situ keratomileusis for the treatment of astigmatism using IR technology was effective and accurate for the treatment of myopic astigmatism.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call