Abstract

The role of rapid on-site evaluation (ROSE) for endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) of pancreatic lesions is debatable. In this study, we aimed to compare the diagnostic yield of ROSE vs. non-ROSE in solid pancreatic lesions. This retrospective single-center study included patients undergoing EUS-FNA of solid pancreatic lesions from 2019-2021. Patients with cystic lesions, those undergoing fine-needle core biopsy, those undergoing repeat procedures, and patients with non-diagnostic smears with less than 6-month follow up were excluded. The diagnostic yield, need for repeat procedures and number of passes required with and without ROSE were analyzed in these patients. Of the 111 patients included, 56 underwent ROSE. The majority of lesions were malignant in both groups (79.6% ROSE vs. 75% non-ROSE). The diagnostic yield was 96.4% in the ROSE group and 94.5% in the non-ROSE group. Repeat samples were needed in 1 ROSE and 2 non-ROSE patients. The median number of passes made was significantly fewer in the ROSE group (3.5, interquartile range - 3,4) compared with the non-ROSE group (4, interquartile range - 3,5) P=0.01. However, the frequency of procedure-related complications was similar in both groups. The utilization of ROSE during EUS-FNA of solid pancreatic lesions does not affect the diagnostic yield or the need for repeat samples, but reduces the number of passes needed for acquiring samples.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call