Abstract

Several schemes for plant model identification in closed-loop operation including classical direct method, two-step identification and closed-loop output error algorithms are considered. These methods are analyzed and compared in terms of the bias distribution of the estimates for the case that the noise model is estimated as well as the case that a fixed model of noise is considered (output error structure). The problems concerning the filtered direct method which is often used in the iterative identification and control scheme are mentioned. It is shown that these problems may be solved by the closed-loop output error identification method.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.