Abstract
Background Quantitative D-Dimer tests are established methods in the non-invasive diagnostic management to rule out venous thromboembolism (VTE). The diagnostic performance and the clinical efficiency different D-Dimer assays in the exclusion of pulmonary embolism (PE) have not yet been compared in a clinical outcome study. Objective Evaluation of the efficiency and safety of excluding the diagnosis of PE with two different quantitative D-Dimer assays in consecutive patients with clinically suspected PE. Patients and Methods We studied the VTE-failure rate of 2206 consecutive patients with an unlikely clinical probability in whom VIDAS or Tinaquant D-Dimer tests were performed. Results The prevalence of PE in 1238 patients whose D-Dimer level was analyzed with Tinaquant assay was 11%. The VIDAS assay group consisted of 968 patients with a PE prevalence of 13%. The VIDAS assay had a sensitivity of 99.2% (95%CI; 96- > 99.9%), the Tinaquant assay of 97.3% (95%CI; 93 -99%). The negative predictive value (NPV) in the Tinaquant assay group was 99.4% (95%CI 98-99.8%) in comparison to 99.7% (95%CI 99-> 99.9%) in the VIDAS assay group. During 3 month of follow-up, there were no fatal cases of PE among patients with normal D-Dimer and unlikely clinical probability in both D-Dimer assay groups. In addition, the test efficiency of Tinaquant assay was significantly higher in comparison to VIDAS assay (52% vs 42%, p < 0.001). Conclusion Both Tinaquant and VIDAS D-Dimer tests perform equally well in combination with an unlikely clinical probability in excluding PE. The Tinaquant test was shown to be more efficient.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have