Abstract

Two antigen detection systems, Clearview Chlamydia (Unipath Ltd., Bedford, United Kingdom) and Chlamydiazyme (Abbott Laboratories, North Chicago, Ill.), were compared with culture for the diagnosis of chlamydia infection in women attending gynecological clinics. Chlamydia trachomatis was isolated from 43 (4.5%) of the 965 women tested. In comparison with tissue culture, the Clearview Chlamydia and Chlamydiazyme tests had sensitivities of 79.0 and 74.4%, respectively, and both had a specificity of 99.6%. The results show that the Clearview Chlamydia test is comparable to Chlamydiazyme for the detection of C. trachomatis from endocervical specimens in a population with a low prevalence of infection.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.