Abstract
Aim and Objective:The aims were to evaluate the root canal debris removal after irrigation with EndoVac system and to compare its efficacy with Max-i-Probe needles.Materials and Methods:Fifteen matched pairs of single canalled vital teeth with mature apices indicated for extraction were selected. After working length determination and biomechanical preparation, the teeth in the right quadrant were irrigated with EndoVac system and with Max-i-Probe needles in the left quadrant using 3% NaOCl and 17% ethylenediaminetetraacetic acid. Teeth were extracted and marked at 1 and 3 mm from working length and decalcified in Kristenson's solution. Stained histologic slides were observed under trinocular research microscope. Wilcoxon signed-rank test was used for statistical analysis. The statistical significance was set at P < 0.05 and the analysis was performed using SPSS version 11.0 software.Results:No statistical significant difference was found at 3 mm level between the groups. Group I had significantly less debris at 1 mm level.Conclusion:EndoVac performed better in removing debris from the apical thirds of root canals.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.