Abstract
In this paper, a comparison of the calculated neutron noise, i.e. the fluctuation of the neutron flux around its average value assuming that all processes are stationary, is conducted, where the neutron noise is calculated using finite differences alone and with finite differences where the Analytical Nodal Method is used to correct the neutron currents, respectively. It is seen that the lower the frequency of the noise source, the larger difference between the two solutions. The main conclusion from this work is that the gain of calculating the neutron noise using the more sophisticated Analytical Nodal Method compared to the increase of the corresponding computational burden is too little to motivate the use of the ANM.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.