Abstract

Previous studies have shown little agreement between the test methods used to assess the bond strength and the mode of failure of resilient liners. This study evaluated the bond strength characteristics of resilient liners by means of 180-degree peeling and butt tensile strength testing. Seventy-two specimens were divided into peel bond and tensile bond specimen groups and were then subdivided into four test groups to evaluate each resilient liner. Tests were conducted with an Instron universal testing machine at a cross-head speed of 2 mm/minute for the tensile specimens and 5 mm/min for the peel specimens. Tensile bond strength and peel bond strength varied significantly among resilient liners except between Novus and Palasiv-62 liners in tensile testing. The mode of failure of Molloplast-B and Novus liners was significantly different between the tensile bond and peel bond test methods. It was concluded that bond strength characteristics can vary according to the test method used.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.