Abstract
Background:The purpose of this study was to evaluate the value of Tc-99m pertechnetate planar, dual-phase MIBI and MIBI-SPECT images in the determination and localization of parathyroid lesions.Materials and Methods:In this study, 38 patients who underwent operation for primary hyperparathyroidism were included. Tc-99m pertechnetate planar-pinhole imaging of the neck and then MIBI planar and SPECT images in supine position was performed. Late SPECT images were acquired 120 minutes after the injection. Early and late MIBI images were quantitatively evaluated.Results:Of the 38 patients, 30 of them had adenoma, 2 patients had hyperplasia and 6 of them were normal on planar images. Thirty-four of 38 patients were positive on SPECT images. SPECT images of the patients with positive results were matched with pathology results.Conclusion:As a result, Tc-99m pertechnetate planar-pinhole, Tc-99m MIBI planar and SPECT images are useful for localization of parathyroid lesions especially in multinodular thyroid gland. However, US or CT images are necessary for more accurate localization and Tc-99m pertechnetate images are useful for interpreting and comparing with the early and late MIBI images.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.